Page 108 of 126 198-0853-02 Rev F
B.1.12 Setup Command “s”:
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID),
a = Channel ID ( 0 to 2; 0 is a global channel)
Command character and Type – 0=read, 1=set, 2=activate (n/a), 3=ack,
4=nak
Number of fields character and number of fields after the comma, excluding
CRC.
Forward Current Setting – amps
Forward Voltage settting – volts
Source of Current Setting in remote mode (0 = host, 1 = option card, 2 =
standard analog input (not implemented)) (DC operation, home link = 0)
Source of Voltage Setting in remote mode (0 = host, 1 = option card, 2 =
standard analog input (not implemented)) (DC operation, home link = 0)
Current Tolerance - Percent of Setting (0 to 100, 0 = disable tolerance
checks)
Voltage Tolerance – Percent of Setting (0 to 100, 0 = disable tolerance
checks)
XTC Control (0 = manual, 1 = RTC, 2 = ATC)
XTC Units (0=reserved, 1=ATC Amp Min, 2=ATC Amp Hr, 3=reserved,
4=RTC Min, 5=RTC Hr)
XTC Resolution (0=xxxx, 1=xxx.x, 2=xx.xx, 3=x.xxx)
XTC Preset (0 to 9999, units and resolution are dependent on the xtc units
and xtc resolution specified in this command)
Totalizer Units (0=reserved, 1=Amp Min, 2= Amp Hr)
Totalizer Resolution (0=xxxx, 1=xxx.x, 2=xx.xx, 3=x.xxx)
CRC value in ascii decimal
Carriage return and Line feed (0x0D 0x0A)
Examples of Setup Command
Read setup command using device address 1, channel 1
@01.1s0#0,54321
Acknowledge read setup command
@01.0s3#12,47.5fi,24.00fv,2isrc,2vsrc,0it,0vt,2xc,1xn,2xr,10.25xs,1tu,0tr,54321