6.3. Unit Configuration
The “Unit Configuration Menu” is used to configure the power supply. Parameters in this menu
will generally be configured when a unit is installed and will not need to be changed after that.
Settings related to cycle control (current and voltage settings, RTC or ATC settings, etc) which
may require changes related to the process that is running are located in the “Unit Setup Menu”
(see 6.4.Cycle Control Settings for details regarding cycle control settings).
The “Unit Configuration Menu” can only be accessed when the power supply is first powered on.
The “Unit Configuration Menu” is password protected. The default password is “0000”. The
password can be changed from within the “Unit Configuration Menu”.
To enter the “Unit Configuration Menu” use the following procedure. See A.6.Unit Configuration
Menu for more information regarding navigation of the “Unit Configuration Menu”.
1) With the power supply powered off press and hold both encoder switches.
2) While still holding both encoder switches turn the power on.
3) Continue holding both encoder switches until the display shows “Unit” “CFg”, then
release the encoder switches.
4) The unit configuration password must be entered before access to the “Unit
Configuration Menu” is granted. The display shows “Unit CFg COdE” on the top
display and the default password “0000” on the bottom display. If the password has
not been changed from the default then press the voltage encoder switch to enter
the “Unit Configuration Menu”. If the password has been changed then the correct
password must be entered. Rotate the current encoder to adjust the selected digit
(blinking digit). Each press of the current encoder advances the selected digit.
Once the correct code has been entered press the voltage encoder switch to enter
the “Unit Configuration Menu”.
5) Once access to the “Unit Configuration Menu” has been granted the top display will
show “CFg” and the bottom display will show the selected sub menu. Rotating the
current encoder will change the sub menu selection. Pressing the voltage encoder
will enter the selected sub menu.
6) To exit the “Unit Configuration Menu” rotate the current encoder until the display
shows “CFg” “End”, then press the voltage encoder to exit the “Unit Configuration
Menu”. The power supply will restart into its normal mode of operation displaying
the last selected run screen.
6.3.1. Totalizer Configuration
The power supply contains a user configurable totalizer that accumulates amp time while the
power supply outputs current. The “Totalizer Configuration Menu” can be used to configure the
totalizer units and resolution as well as clear the totalizer.
The “Totalizer Configuration Menu” is accessed from the “Unit Configuration Menu” (see 6.3.Unit
Configuration). To enter the “Totalizer Configuration Menu” select the “tot” sub menu from the
“Unit Configuration Menu” and press the voltage encoder. The “Totalizer Configuration Menu” will
show “tot” on the top display and the selected sub menu on the bottom display. For more details
regarding “Totalizer Configuration Menu” navigation see A.6.1.Totalizer Configuration Menu.